The Effect of Surgical Positioning on Pneumocephalus in Subthalamic Nucleus Deep Brain Stimulation Surgery for Parkinson Disease

Published:October 19, 2022DOI:https://doi.org/10.1016/j.neurom.2022.09.003

      Abstract

      Objectives

      This research analyzed the effect of surgical positioning on postoperative pneumocephalus and assessed additional potential risk factors of pneumocephalus in subthalamic nucleus (STN) deep brain stimulation (DBS) for Parkinson disease (PD).

      Materials and Methods

      In this study, 255 consecutive patients with PD who received bilateral STN DBS under general anesthesia were retrospectively included. Of these, 180 patients underwent surgery with their heads in an elevated position, and 75 patients underwent surgery in a supine position. The postoperative pneumocephalus volume was compared between the two groups. Other potential risk factors for pneumocephalus also were analyzed.

      Results

      The mean pneumocephalus volume for the group with elevated-head positioning (16.76 ± 15.23 cm3) was greater than for the supine group (3.25 ± 8.78 cm3) (p < 0.001). Multivariable analysis indicated that the pneumocephalus volume was related to surgical positioning, lateral trajectory angle, intraoperative mean arterial pressure (MAP), microelectrode recording (MER) passage number, brain atrophy degree, and the anterior trajectory angle. No correlation was found between pneumocephalus and age, sex, duration of PD, surgery length, or intracranial volume. In the subgroup analysis, the pneumocephalus volume exhibited a negative correlation with intraoperative MAP (r = −0.210, p = 0.005) and positive correlations with degree of brain atrophy (r = 0.242, p = 0.001) and MER passage number (r = 0.184, p = 0.014) in the elevated-head group. Specifically, an MER passage number > 3 was a significant risk factor for pneumocephalus in the elevated-head group. A positive correlation was observed between the pneumocephalus volume and the lateral trajectory angle in both groups (elevated-head positioning, r = 0.153, p = 0.041; supine positioning, r = 0.546, p < 0.001).

      Conclusions

      In patients with PD who were anesthetized and receiving STN DBS, supine positioning reduced pneumocephalus volume compared with patients with PD receiving STN DBS with their heads elevated. The pneumocephalus volume was negatively correlated with intraoperative MAP and positively correlated with the degree of brain atrophy, the lateral trajectory angle, and the MER passage number.

      Keywords

      To read this article in full you will need to make a payment

      Purchase one-time access:

      Academic & Personal: 24 hour online accessCorporate R&D Professionals: 24 hour online access
      One-time access price info
      • For academic or personal research use, select 'Academic and Personal'
      • For corporate R&D use, select 'Corporate R&D Professionals'

      Subscribe:

      Subscribe to
      Already a print subscriber? Claim online access
      Already an online subscriber? Sign in
      Institutional Access: Sign in to ScienceDirect

      References

        • Beggio G.
        • Raneri F.
        • Rustemi O.
        • Scerrati A.
        • Zambon G.
        • Piacentino M.
        Techniques for pneumocephalus and brain shift reduction in DBS surgery: a review of the literature.
        Neurosurg Rev. 2020; 43: 95-99https://doi.org/10.1007/s10143-019-01220-2
        • Matias C.M.
        • Frizon L.A.
        • Asfahan F.
        • Uribe J.D.
        • Machado A.G.
        Brain shift and pneumocephalus assessment during frame-based deep brain stimulation implantation with intraoperative magnetic resonance imaging.
        Oper Neurosurg (Hagerstown). 2018; 14: 668-674https://doi.org/10.1093/ons/opx170
        • Azmi H.
        • Machado A.
        • Deogaonkar M.
        • Rezai A.
        Intracranial air correlates with preoperative cerebral atrophy and stereotactic error during bilateral STN DBS surgery for Parkinson's disease.
        Stereotact Funct Neurosurg. 2011; 89: 246-252https://doi.org/10.1159/000327916
        • Albano L.
        • Rohatgi P.
        • Kashanian A.
        • Bari A.
        • Pouratian N.
        Symptomatic pneumocephalus after deep brain stimulation surgery: report of 2 cases.
        Stereotact Funct Neurosurg. 2020; 98: 30-36https://doi.org/10.1159/000505078
        • Nazzaro J.M.
        • Lyons K.E.
        • Honea R.A.
        • et al.
        Head positioning and risk of pneumocephalus, air embolism, and hemorrhage during subthalamic deep brain stimulation surgery.
        Acta neurochir. 2010; 152: 2047-2052https://doi.org/10.1007/s00701-010-0776-5
        • Coenen V.A.
        • Abdel-Rahman A.
        • McMaster J.
        • Bogod N.
        • Honey C.R.
        Minimizing brain shift during functional neurosurgical procedures - a simple burr hole technique that can decrease CSF loss and intracranial air.
        Cent Eur Neurosurg. 2011; 72: 181-185https://doi.org/10.1055/s-0031-1279748
        • Takumi I.
        • Mishina M.
        • Hironaka K.
        • et al.
        Simple solution for preventing cerebrospinal fluid loss and brain shift during multitrack deep brain stimulation surgery in the semisupine position: polyethylene glycol hydrogel dural sealant capping: rapid communication.
        Neurol Med Chir (Tokyo). 2013; 53: 1-6https://doi.org/10.2176/nmc.53.1
        • Piacentino M.
        • Beggio G.
        • Rustemi O.
        • Zambon G.
        • Pilleri M.
        • Raneri F.
        Pneumocephalus in subthalamic deep brain stimulation for Parkinson's disease: a comparison of two different surgical techniques considering factors conditioning brain shift and target precision.
        Acta Neurochir. 2021; 163: 169-175https://doi.org/10.1007/s00701-020-04635-9
        • Sharim J.
        • Pezeshkian P.
        • DeSalles A.
        • Pouratian N.
        Effect of cranial window diameter during deep brain stimulation surgery on volume of pneumocephalus.
        Neuromodulation. 2015; 18 ([discussion: 578–579]. https://doi.org/10.1111/ner.12328): 574-578
        • Sasaki T.
        • Agari T.
        • Kuwahara K.
        • et al.
        Efficacy of dural sealant system for preventing brain shift and improving accuracy in deep brain stimulation surgery.
        Neurol Med Chir (Tokyo). 2018; 58: 199-205https://doi.org/10.2176/nmc.oa.2017-0242
        • Krauss P.
        • Van Niftrik C.H.B.
        • Muscas G.
        • Scheffler P.
        • Oertel M.F.
        • Stieglitz L.H.
        How to avoid pneumocephalus in deep brain stimulation surgery? Analysis of potential risk factors in a series of 100 consecutive patients.
        Acta Neurochir. 2021; 163: 177-184https://doi.org/10.1007/s00701-020-04588-z
        • Ko A.L.
        • Magown P.
        • Ozpinar A.
        • Hamzaoglu V.
        • Burchiel K.J.
        Asleep deep brain stimulation reduces incidence of intracranial air during electrode implantation.
        Stereotact Funct Neurosurg. 2018; 96: 83-90https://doi.org/10.1159/000488150
        • Schneider G.H.
        • von Helden G.H.
        • Franke R.
        • Lanksch W.R.
        • Unterberg A.
        Influence of body position on jugular venous oxygen saturation, intracranial pressure and cerebral perfusion pressure.
        Acta Neurochir Suppl (Wien). 1993; 59: 107-112https://doi.org/10.1007/978-3-7091-9302-0_19
        • Feldman Z.
        • Kanter M.J.
        • Robertson C.S.
        • et al.
        Effect of head elevation on intracranial pressure, cerebral perfusion pressure, and cerebral blood flow in head-injured patients.
        J Neurosurg. 1992; 76: 207-211https://doi.org/10.3171/jns.1992.76.2.0207
        • Bergsneider M.
        • Yang I.
        • Hu X.
        • McArthur D.L.
        • Cook S.W.
        • Boscardin W.J.
        Relationship between valve opening pressure, body position, and intracranial pressure in normal pressure hydrocephalus: paradigm for selection of programmable valve pressure setting.
        Neurosurgery. 2004; 55 ([discussion: 858–859]. https://doi.org/10.1227/01.neu.0000137631.42164.b8): 851-858

      Comment